  fast-acting cubefuse ups/critical applications carton quantity and weight amp carton weight per carton rating qty. lbs kg fcf-1-30 12 1.39 0.63 fcf-35-60a 12 1.42 0.65 fcf-70-100a 6 1.74 0.79 ccpb 1-, 2- & 3-pole disconnects for the quik-spec coordination panelboard. data sheet 1160 tcfh_n 100, 60 & 30a holders. data sheet 9007 ccp_cf 1-, 2- & 3-pole switched disconnects data sheet 1157 cubefuse holders, disconnects and panelboards the cubefuse is used in the following cooper bussmann products. 0412 bu-sb10811 page 1 of 2 data sheet 2147 catalog symbol: fcf_rn fast-acting fuse: 4 minutes maximum clearing time at 200% rated current for 1 to 30a fuse 6 minutes maximum clearing time at 200% rated current for 35 to 60a fuse 8 minutes maximum clearing time at 200% rated current for 70 to 100a fuse amp ratings: 1 to 100a voltage ratings: 600vac/dc interrupting ratings: 1-60a 300ka rms sym. (ul) 200ka rms sym. (csa) 50ka dc (ul & csa) interrupting ratings: 70-100a 200ka rms sym. (ul) 200ka rms sym. (csa) 50ka dc (ul & csa) agency information: ?ul listed fuse: guide jfhr, file e4273 ?csa certified fuse: class 1422- 02, file 53787 ?ce compliance for the european union low voltage directive ?rohs compliant other ratings/specifications: watts loss at rated current: fcf15rn: 3.48w fcf30rn: 5.45w fcf60rn: 7.27w fcf100rn: 11.50w operating and storage temperature range: -40 to 80? material specifications: ?case: glass filled pes (polyethersulfone) ?terminals: copper alloy ?terminal plating: electroless tin features and product benefits the worlds first finger-safe power fuse system. smallest footprint of any class fuse including class j, cc, t and rk. class cf meets class j fast-acting electrical performance requirements. faster response to damaging faults to help reduce destructive thermal and magnetic forces. true fast-acting fuse construction. high interrupting rating to safely interrupt faults up to 300ka. no venting of arc or molten metal and gases during opening. low let-through currents under fault conditions. catalog numbers (amp rating) non-indicating cubefuse fcf1rn fcf3rn fcf6rn fcf10rn fcf15rn fcf20rn fcf25rn fcf30rn fcf35rn fcf40rn fcf45rn fcf50rn fcf60rn fcf70rn fcf80rn FCF90RN fcf100rn
fcf_rn dimensions ?in (mm) time-current characteristic curves?verage melt current limitation curves 1a 3a 6a 10a 15a 20a 30a 40a 50a 100a 60a 0.01 0.1 1 10 100 1000 1 10 100 1,000 10,000 time in seconds current in amps a 30a 60a 15a 100a 100 1,000 10,000 100,000 100 1,000 10,000 100,000 instantaneous peak let thru current in amperes prospective short circuit curr ent (symmetrical rms amps) b 300,000 0412 bu-sb10811 page 2 of 2 data sheet 2147 fuse dimensions - in (mm) amps a b c d e f g 1-15 1.88 0.75 1.00 0.23 0.04 0.63 0.28 (47.75) (19.05) (25.40) (5.84) (1.02) (15.93) (7.11) 20 1.88 0.75) 1.00 0.31 0.04 0.63 0.28 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 25-30 1.88 0.75 1.00 0.31 0.04 0.63 0.28 (47.75) (19.05) (25.40) (7.87) (1.02) (15.93) (7.11) 35-40 2.13 1.00 1.13 0.36 0.04 0.63 0.38 (54.10) (25.40) (28.58) (9.10) (1.02) (15.93) (9.65) 45-50 2.13 1.00 1.13 0.44 0.04 0.63 0.38 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 60 2.13 1.00 1.13 0.44 0.04 0.63 0.38 (54.10) (25.40) (28.58) (11.13) (1.02) (15.93) (9.65) 70 3.01 1.00 1.26 0.49 0.06 0.58 0.38 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 80-90 3.01 1.00 1.26 0.49 0.06 0.58 0.38 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 100 3.01 1.00 1.26 0.49 0.06 0.58 0.38 (76.45) (25.40) (32.00) (12.45) (1.60) (14.78) (9.65) 2012 cooper bussmann www.cooperbussmann.com the only controlled copy of this data sheet is the electronic read-only version located on the cooper bussmann network drive. all other copies of this document are by definition uncontrolled. this bulletin is intended to clearly present comprehensive product data and provid e technical informa- tion that will help the end user with design applications. cooper bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. cooper bussmann also reserves the right to change or updat e, without notice, any technical information contained in this bulletin. once a product has been selected, it should be tested by the user in all po ssible applications.


▲Up To Search▲   

 
Price & Availability of FCF90RN

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X